Hidier Power Group (Beijing) Co., Ltd.

                  Green Power, Hidier Power

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsPerkins Diesel Generators

8KW Perkins Diesel Generators Set With Water Cooled System , 50 / 60HZ

I'm Online Chat Now
Certification
Good quality Kohler Diesel Generator for sales
Good quality Kohler Diesel Generator for sales
Hidier is a great brand. As a distributor, we feel content to its quality, service and hope we can go on this win-win relationship.

—— Julie Thomson

We purchased an 800KW Cummins diesel generator from Hidier. Hidier is as good as world famous brand! They had office in my country.

—— Alexander Zverev

8KW Perkins Diesel Generators Set With Water Cooled System , 50 / 60HZ

large.img.alt
small.img.alt small.img.alt small.img.alt

Large Image :  8KW Perkins Diesel Generators Set With Water Cooled System , 50 / 60HZ Get Best Price

Product Details:
Place of Origin: Perkins Engine, assembled in China
Brand Name: HIDIER-Perkins
Certification: CE, CSA, NOISE, GS, EC-II, EPA, CARB, GOST.
Model Number: HDP8/S
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Plywood box
Delivery Time: Within 30 days
Payment Terms: T/T, L/C
Supply Ability: 1000pcs/week
Detailed Product Description
Output Capacity: 9/10kVA Output Power: 7/8kW
Genset Type: Hidier Engine: Perkins
Frequency: 50Hz / 60Hz Cooling Type: Water Cooled

Perkins Diesel Generator Set With Water Cooled System.8KW 50 / 60HZ

 

 HDP Series               HDP8/ HDP8S  

Model

Standby Power

Prime Power

Engine

Alternator

Control Panel

KVA

KW

KVA

KW

Stamford

Hidier(Optional)

Model

HDP8/S

10

8

9

7

403D-11G

PI044E

HD8

MRS10

 Spec #1.1 Features

1

Excitation system: self-excited (AREP and PMG are optional)

2

ATS (automatic transfer switch) receptacle

3

Lockable battery isolator switch

4

Stainless galvanized zinc plates with strong corrosion resistance

5

Vibration isolators between the engine/alternator and base frame

6

Integrated wiring design

7

Base fuel tank for at least 8 hours running

8

Equipped with an industrial muffler

9

50℃ radiator

10

Top lifting and steel base frame with forklift holes

11

Drainage for fuel tank

12

Complete protection functions and safety labels

13

IP54 (soundproof sets), IP56 (control system)

14

Water jacket preheater, oil heater are available.

15

Double air cleaner, spare parts, special tools are available.

16

Custom-made is acceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8KW Perkins Diesel Generators Set With Water Cooled System ,  50 / 60HZ  Ratings and Performance Data
Engine Brand & Model: Perkins 403D-11G
Alternator Brand & Model: Stamford PI044E
Control System: ComAp InteliLite®MRS10
Noise Level@7m: 70.9-75.8
Frequency & Phase: 50Hz/60Hz & 3 Phase
Engine Speed: RPM 1500/1800
8KW Perkins Diesel Generators Set With Water Cooled System ,  50 / 60HZ Structure Type: HDP8
HDP8S
Fuel Tank Capacity: L HDP8  50
HDP8S   100
Fuel Consumption: l/hr (100% Load) Prime   /
Standby   /
Generator Set Length (L) Width (W) Height (H) Net Weight kg
       Model mm mm mm
HDP8 1500 700 1200 350
HDP8S 1900 700 1200 530

Spec #1.2 Container Calculation

Generator Set Model

20’GP

pcs

40‘GP

pcs

40‘HQ

pcs

Efficiency

HDP8

N/A

N/A

N/A

N/A

HDP8S

N/A

N/A

N/A

N/A

Spec#2  Engine         Perkins 403D-11G

 

8KW Perkins Diesel Generators Set With Water Cooled System ,  50 / 60HZ

Spec #2.1 General Data

Number of cylinders

3

Cylinder arrangement

/

Cycle

4 stroke

Induction system

Turbocharged

Combustion system

Indirect injection

Compression ratio

23:1

Bore and Stroke

77 x 81 mm

(3.3 x 3.5 in)

Cubic capacity

1.496litres

Direction of rotation

Anti-clockwise viewed on flywheel

Cooling system

Water cooled

Total coolant capacity

5.2litres

Total lubrication system capacity

4.9 litres (62.7 US gals)

Dimensions

L776mm 

W449mm 

H700mm

Total weight (dry)

129.2kg 

 

 

Spec #2.2 Engine Output

Speed

rpm

Run Type

Typical Output (Net)

Engine Power

Gross

Net

kVA

kWe

kWm

hp

kWm

hp

1500

Prime

9.0

7.2 8.6 11.5 8.5 11.3

Standby

10

8.0 9.5 12.7 9.3 12.4

1800

Prime

11.2

9.0 10.7 14.3 10.3 13.9

Standby

12.4

9.9 11.8 15.8 11.4 15.3

  *Subject to conformance with ASTM D6751 and EN14214.

The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8.

Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2.

Rating Definitions:

Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours operation.

Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.

 

Spec #2.3 Fuel System

Type of injection

Indirect injection

Fuel injection pump

Cassette type

Fuel injector

Pintle nozzle

Nozzle opening pressure

14,7 MPa

Max particle size

25 microns

Fuel lift pump

-type

mechanical (camshaft driven)

-flow/hour

63 litres/hr

-pressure

10 kPa

Maximum suction head

0,8 m

Maximum static pressure head

3,0 m

Engine Speed

1500 rpm

g/kWh

l/hr

Standby

261

2.9

Prime Power

252

2.6

75% of prime power

258

2.0

50% of prime power

286

2.0

 

Spec #2.4 Cooling System

Radiator

face area

0.147m²

rows and materials

2 row, Aluminium

matrix density and material

14.5 FPI Aluminium

width of matrix

334 mm

height of matrix

440 mm

pressure cap setting

90 kPa

Fan

diameter

320 mm

drive ratio

1,285:1

number of blades

7

material

Plastic

type

pusher

Coolant

Total system capacity

 

-with radiator

5.2 litres

-without radiator...

1.9 litres

Maximum top tank temperature

30,4 kPa

Temperature rise across engine

tba °C

Shutdown switch setting

118 °C

Max permissible external system resistance

tba kPa

Thermostat operation range.

75 - 87°C.

Recommended coolant:

Recommended coolant: 50% anti freeze / 50% water. For complete

details of recommended coolant specifications, refer to the

Operation and Maintenance Manual for this engine model

Ambient clearance50% Glycol

Duct allowancePa

m³/sec

53℃

0

0.67

46℃

125

0.44

 

Spec #2.5 Exhaust System

Maximum back pressure

102 kPa

Exhaust outlet size-horizontal

34 mm

Exhaust outlet size- -vertical

40 mm

 

Spec #2.6 Induction System

Maximum air intake restriction

clean filter

3,0kPa

dirty filter

6,4 kPa

Air filter type

dry element type

 

Spec #2.7 Electrical System

Alternator

15 / 40 amps -12 V

-starter motor

Bosch 1,1 kW -12 V

Alternator output

/

Starter

/

Starter motor voltage

/

Starter motor power

/

Cold start recommendations

Minimum cranking speed

150 rev/min

Minimum

starting

temperature

Grade of

engine

lubricating

oil

Battery specifications

°C

BS3911

Cold

start

amps

SAEJ537

Cold

cranking

amps

Number

of

batteries

needed

Commercial

ref number

0

20W

340

540

1

069

-15

10W

340

540

1

069

-20

5W

540

590

1

072

Note: Battery capacity is defined by the 20 hour rate

Note: If a change to a low viscosity oil is made, the cranking torque necessary at low ambient temperatures is much reduced. The starting equipment has been selected to take advantage of this.

It is important to change to the appropriate multigrade oil in anticipation of operating in low ambient temperatures

Spec #2.8 Lubrication System

Lubricating oil capacity

Max. sump capacity

4,4 litres

Min. sump capacity

4,9 litres

Maximum oil capacity in sump

3,4 litres

Maximum engine operating angles -

Front up, front down, right side, left side e

35°

Sump drain plug tapping size

/

Shutdown switch setting (where fitted)

Oil pressure shut down switch

/

Lubricating oil pressure

-relief valve opens..

262 - 359 kPa

Minimum oil pressure.

120 kPa

Maximum continuous oil temperature (in rail)

125°C

Oil flow at rated speed

6.6 litres /min

 

Spec#3  Alternator     StamfordPI044E / Hidier HD7

CONTROL SYSTEM

STANDARD AS480 AVR (SELF EXCITED)

VOLTAGE REGULATION

± 1.0 %

SUSTAINED SHORT CIRCUIT

SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT

CONTROL SYSTEM

AS480 AVR WITH OPTIONAL EXCITATION BOOST SYSTEM (EBS)

SUSTAINED SHORT CIRCUIT

REFER TO SHORT CIRCUIT DECREMENT CURVE (page 7)

INSULATION SYSTEM

CLASS H

PROTECTION

IP23

RATED POWER FACTOR

0.8

STATOR WINDING

SINGLE LAYER CONCENTRIC

WINDING PITCH

TWO THIRDS

WINDING LEADS

4

STATOR WDG. RESISTANCE

0.588 Ohms AT 22°C  SERIES CONNECTED

ROTOR WDG. RESISTANCE

0.415 Ohms at 22°C

EXCITER STATOR RESISTANCE

17.5 Ohms at 22°C

EXCITER ROTOR RESISTANCE

0.211 Ohms PER PHASE AT 22°C

EBS STATOR RESISTANCE

12.9 Ohms at 22°C

R.F.I. SUPPRESSION

BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION

NO LOAD < 1.5%  NON-DISTORTING LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

2250 Rev/Min

BEARING DRIVE END

BALL. 6309-2RS (ISO)

BEARING NON-DRIVE END

BALL. 6306-2RS (ISO)

 

1 BEARING

2 BEARING

 

WITH   EBS

WITHOUT   EBS

WITH   EBS

WITHOUT   EBS

WEIGHT COMP. GENERATOR

80 kg

78.3 kg

83 kg

81.3 kg

WEIGHT WOUND STATOR

27 kg

27 kg

27 kg

27 kg

WEIGHT WOUND ROTOR

27.87 kg

26.17 kg

28.87 kg

27.17 kg

WR² INERTIA

0.0953 kgm2

0.0952 kgm2

0.097 kgm2

0.0953 kgm2

SHIPPING WEIGHTS in a crate

100 kg

98.3 kg

109 kg

107.3 kg

PACKING CRATE SIZE

71 x 51 x 67 (cm)

71 x 51 x 67 (cm)

TELEPHONE INTERFERENCE

THF<2%

TIF<50

COOLING AIR

0.135 m³/sec  286 cfm

VOLTAGE SERIES

220

230

240

VOLTAGE PARALLEL

110

115

120

POWER FACTOR

0.8

1.0

0.8

1.0

0.8

1.0

kVA BASE RATING FOR REACTANCE VALUES

 

7.7

 

10.0

 

8.0

 

10.0

 

8.4

 

10.0

Xd DIR. AXIS SYNCHRONOUS

2.26

2.94

2.15

2.69

2.07

2.46

X'd DIR. AXIS TRANSIENT

0.23

0.30

0.22

0.28

0.21

0.25

X''d DIR. AXIS SUBTRANSIENT

0.15

0.19

0.15

0.19

0.14

0.17

Xq QUAD. AXIS REACTANCE

1.09

1.42

1.04

1.30

1.00

1.19

X''q QUAD. AXIS SUBTRANSIENT

0.24

0.31

0.23

0.29

0.22

0.26

XL LEAKAGE REACTANCE

0.09

0.12

0.08

0.10

0.08

0.10

X2 NEGATIVE SEQUENCE

0.20

0.26

0.19

0.24

0.18

0.21

X0 ZERO SEQUENCE

0.09

0.12

0.08

0.10

0.08

0.10

REACTANCES ARE SATURATED                                       VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED

T'd TRANSIENT TIME CONST.

0.008 s

T''d SUB-TRANSTIME CONST.

0.002 s

T'do O.C. FIELD TIME CONST.

0.17 s

Ta ARMATURE TIME CONST.

0.007 s

SHORT CIRCUIT RATIO

1/Xd

Spec#4 Control System ComAp InteliLite® MRS10

8KW Perkins Diesel Generators Set With Water Cooled System ,  50 / 60HZ

 

 

 

8KW Perkins Diesel Generators Set With Water Cooled System ,  50 / 60HZ

Spec #4.1 Features

1

Automatic or manual start/stop of the gen-set

2

Push buttons for simple control, lamp test

3

Lockable battery isolator switch

4

Graphic back-lit LCD display 128×64 pixels

5

2 LED indicators

6

Integrated wiring design

7

Parameters adjustable via keyboard or PC

8

Generator measurements (50/60 Hz):U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh

9

Selectable protections alarm/ shutdown

10

3 phase Generator protections

– Over-/under voltage

– Over-/under frequency

– Current/voltage asymmetry

– Overcurrent/overload

11

Analog oil pressure, water, temperature, fuel level, battery, voltage, engine speed (pick-up)

12

Configurable programmable inputs and outputs

13

Warm-up and cooling functions

14

RS232 interface (AT-LINK CONV cable is necessary for IL-MRS 10)

15

Dimensions 180×120 mm (front panel)

16

Sealed to IP65

17

Custom-made is acceptable

Spec #4.2 Functions

Binary inputs/oupputs

6/6

Analog inputs

3

Pick-up

-

AMF function

-

Input configuration

Output configuration

Voltage measurement Gen./Mains

3ph/-

Current measurement

3ph

KW/KWH measurement

●/-

GCB/MCB control with feedback

 

Extension units(periph)

-

Communication interfaces

Rs232

Modem support

-

Battery charging alternator circuit

Spec #5 Options

 

Items

Options

Select

Engine

Water Jacket Preheater

 

Oil Preheater

 

Alternator

Winding Temperature Measuring Instrument

 

Alternator Preheater

 

PMG

 

Anti-damp and anti-corrosion treatment

 

Anti-condensation heater

 

Generator Set

Tools with the machine

STND

Fuel System

Low fuel level alarm

 

Automatic fuel feeding system

 

Fuel T-valves

 

Enclosure

Open Type

 

Silent/Super Silent Type

 

Trailer Type

 

Canopy/Enclosure Type

 

Lubricating sys

Oil with the machine

 

Exhaust Sys.

Protection board from hotness

 

Cooling Sys.

Front heat protection

 

Coolant (-30°C)

 

Control System

Remote Control System

 

ATS Control System

 

Auto Synchronizing System

 

Generator Set Output Cabinet

 

Control Panel

Czech·ComAp

STND

China·Hidier

 

Denmark·Deif

 

U.K.·Deepsea

 

Voltages

415/240V

 

400/230V

 

380/220V

 

220/127V

 

200-115V

 

 

Contact Details
Hidier Power Group (Beijing) Co., Ltd.

Contact Person: Mr. Yang Congli(Colin)

Tel: +86 13370160269

Fax: 86-10-59602578

Send your inquiry directly to us