Hidier Power Group (Beijing) Co., Ltd.

                  Green Power, Hidier Power

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsPerkins Diesel Generators

18KW Silent Type 4 Stoke Perkins Diesel Generators With Water Cooling

I'm Online Chat Now
Certification
Good quality Kohler Diesel Generator for sales
Good quality Kohler Diesel Generator for sales
Hidier is a great brand. As a distributor, we feel content to its quality, service and hope we can go on this win-win relationship.

—— Julie Thomson

We purchased an 800KW Cummins diesel generator from Hidier. Hidier is as good as world famous brand! They had office in my country.

—— Alexander Zverev

18KW Silent Type 4 Stoke Perkins Diesel Generators With Water Cooling

large.img.alt
small.img.alt small.img.alt small.img.alt

Large Image :  18KW Silent Type 4 Stoke Perkins Diesel Generators With Water Cooling Get Best Price

Product Details:
Place of Origin: Perkins Engine, assembled in China
Brand Name: HIDIER-Perkins
Certification: CE, CSA, NOISE, GS, EC-II, EPA, CARB, GOST.
Model Number: HDP18/S
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Plywood box
Delivery Time: Within 30 days
Payment Terms: T/T, L/C
Supply Ability: 1000pcs/week
Detailed Product Description
Engine: Perkins Genset Type: Hidier
Frequency: 50Hz / 60Hz Cycle: 4 Stoke
Number Of Cylinders: 4 Compression Ratio: 23.3:1

Silent Type 4 Stoke Diesel Generator  With Water Cooling , 18KW 50 / 60HZ

 

 HDP Series               HDP18/ HDP18S  

Model

Standby Power

Prime Power

Engine

Alternator

Control Panel

KVA

KW

KVA

KW

Stamford

Hidier(Optional)

Model

HDP18/S

22

18

20

16

404D-22G

PI144D

HD16

MRS10

 Spec #1.1 Features

1

Excitation system: self-excited (AREP and PMG are optional)

2

ATS (automatic transfer switch) receptacle

3

Lockable battery isolator switch

4

Stainless galvanized zinc plates with strong corrosion resistance

5

Vibration isolators between the engine/alternator and base frame

6

Integrated wiring design

7

Base fuel tank for at least 8 hours running

8

Equipped with an industrial muffler

9

50℃ radiator

10

Top lifting and steel base frame with forklift holes

11

Drainage for fuel tank

12

Complete protection functions and safety labels

13

IP54 (soundproof sets), IP56 (control system)

14

Water jacket preheater, oil heater are available.

15

Double air cleaner, spare parts, special tools are available.

16

Custom-made is acceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18KW Silent Type 4 Stoke Perkins Diesel Generators  With Water Cooling  Ratings and Performance Data
Engine Brand & Model: Perkins 403D-22G
Alternator Brand & Model: Stamford PI144D
Control System: ComAp InteliLite®MRS10
Noise Level@7m: 70.9-75.8
Frequency & Phase: 50Hz/60Hz & 3 Phase
Engine Speed: RPM 1500/1800
18KW Silent Type 4 Stoke Perkins Diesel Generators  With Water Cooling Structure Type: HDP18
HDP18S
Fuel Tank Capacity: L HDP18  60
HDP18S   100
Fuel Consumption: l/hr (100% Load) Prime   /
Standby   /
Generator Set Length (L) Width (W) Height (H) Net Weight kg
       Model mm mm mm
HDP18 1600 700 1300 500
HDP18S 2100 700 1200 700

Spec #1.2 Container Calculation

Generator Set Model

20’GP

pcs

40‘GP

pcs

40‘HQ

pcs

Efficiency

HDP18

N/A

N/A

N/A

N/A

HDP18S

N/A

N/A

N/A

N/A

Spec#2  Engine         Perkins 404D-22G

 

18KW Silent Type 4 Stoke Perkins Diesel Generators  With Water Cooling

Spec #2.1 General Data

Number of cylinders

4

Cylinder arrangement

Vertical in-line

Cycle

4 stroke

Induction system

Turbocharged

Combustion system

Indirect injection

Compression ratio

23.3:1

Bore and Stroke

84 x 100 mm

(3.3 x 3.9 in)

Cubic capacity

2.216litres

Direction of rotation

Anti-clockwise viewed on flywheel

Cooling system

Water cooled

Total coolant capacity

9.3litres

Total lubrication system capacity

10.6 litres (62.7 US gals)

Dimensions

L973mm 

W590mm 

H973mm

Total weight (dry)

242kg 

 

 

Spec #2.2 Engine Output

Speed

rpm

Run Type

Typical Output (Net)

Engine Power

Gross

Net

kVA

kWe

kWm

hp

kWm

hp

1500

Prime

20.3

16.2 18.7 25.1 18.4 24.7

Standby

22.3

17.8 20.6 27.6 20.3 27.2

1800

Prime

24.2

19.3 22.0 29.5 21.7 29.1

Standby

26.6

21.3 24.3 32.6 23.9 32.1

  *Subject to conformance with ASTM D6751 and EN14214.

The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8.

Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2.

Rating Definitions:

Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours operation.

Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.

Spec #6.3 Fuel System

Type of injection

Indirect injection

Fuel injection pump

Cassette type

Fuel injector

Pintle nozzle

Nozzle opening pressure

14,7 MPa

Max particle size

25 microns

Fuel lift pump

-type

mechanical (camshaft driven)

-flow/hour

63 litres/hr

-pressure

10 kPa

Maximum suction head

0,8 m

Maximum static pressure head

3,0 m

Engine Speed

1500 rpm

g/kWh

l/hr

Standby

244

6.1

Prime Power

237

5.3

75% of prime power

238

4.0

50% of prime power

258

2.9

 

Spec #6.4 Cooling System

Radiator

face area

0.3 m²

rows and materials

1 row, Aluminium

matrix density and material

54 tubes / row

width of mat

570 mm

height of matrix

524.2 mm

pressure cap setting

110kPa

Estimated cooling air flow reserve

kPa

Fan

diameter

457.2 mm

drive ratio

1.1 :1

number of blades

7

material

plastic

type

pusher

Coolant

Total system capacity

-with radiator         9.32 litres

-without radiator       3.6 litres

Maximum top tank temperature

112 °C

Temperature rise across engine

7.5 °C

Max permissible external system resistance

kPa

Thermostat operation range

82 - 95 °C

Max. static pressure head on pump

30.4 kPa

Recommended coolant

50% anti freeze / 50% water. For complete details of recommended coolant specifications, refer to the

Operation and Maintenance Manual for this engine model.

Duct allowance

Maximum additional restriction (duct allowance) to cooling airflow and resultant minimum airflow

Ambient clearance 50% Glycol

Duct allowance Pa

m³/sec

N/A

N/A

N/A

Spec #6.5 Exhaust System

Maximum back pressure

102 kPa

Exhaust outlet size

42mm

Spec #6.6 Induction System

Maximum air intake restriction

clean filter

30kPa

dirty filter

64 kPa

Air filter type

dry element type

Spec #6.7 Electrical System

type

12V negative grounding

alternator

65 amps, 12 V

starter motor

Delco Remy, 12 V

starter solenoid pull-in current

TBA

starter solenoid hold-in current

TBA

Number of teeth on starter pinion

9

Number of teeth on flywheel

126

Cold start recommendations

Minimum engine cranking speed over TDC

150 rev/min

Minimum

starting

temperature

Grade of

engine

lubricating

oil

Battery specifications

°C

BS3911

Cold

start

amps

SAEJ537

Cold

cranking

amps

Number

of

batteries

needed

Commercial

ref number

0

20W

540

740

1

647

-15

10W

540

740

1

647

-20

5W

600

780

1

655

Note: Battery capacity is defined by the 20 hour rate

Note: If a change to a low viscosity oil is made, the cranking torque necessary at low ambient temperatures is much reduced. The starting equipment has been selected to take advantage of this.

It is important to change to the appropriate multigrade oil in anticipation of operating in low ambient temperatures

Spec #6.8 Lubrication System

Lubricating oil capacity

Max. sump capacity

60 litres

Min. sump capacity

45 litres

Maximum oil capacity in sump

/

Maximum engine operating angles -

Front up, front down, right side, left side e

35°

Sump drain plug tapping size

/

Shutdown switch setting (where fitted)

Oil pressure shut down switch

/

Lubricating oil pressure

-relief valve opens..

/

Minimum oil pressure.

/

Maximum continuous oil temperature (in rail)

125°C

Oil flow at rated speed

/

Spec#3  Alternator     StamfordPI044E / Hidier HD7

CONTROL SYSTEM

STANDARD AS480 AVR (SELF EXCITED)

VOLTAGE REGULATION

± 1.0 %

SUSTAINED SHORT CIRCUIT

SELF EXCITED MACHINES DO NOT SUSTAIN A SHORT CIRCUIT CURRENT

CONTROL SYSTEM

AS480 AVR WITH OPTIONAL EXCITATION BOOST SYSTEM (EBS)

SUSTAINED SHORT CIRCUIT

REFER TO SHORT CIRCUIT DECREMENT CURVE (page 7)

INSULATION SYSTEM

CLASS H

PROTECTION

IP23

RATED POWER FACTOR

0.8

STATOR WINDING

SINGLE LAYER CONCENTRIC

WINDING PITCH

TWO THIRDS

WINDING LEADS

4

STATOR WDG. RESISTANCE

0.138 Ohms AT 22°C  SERIES CONNECTED

ROTOR WDG. RESISTANCE

0.657 Ohms at 22°C

EXCITER STATOR RESISTANCE

18.5 Ohms at 22°C

EXCITER ROTOR RESISTANCE

0.228 Ohms PER PHASE AT 22°C

EBS STATOR RESISTANCE

12.9 Ohms at 22°C

R.F.I. SUPPRESSION

BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others

WAVEFORM DISTORTION

NO LOAD < 1.5%  NON-DISTORTING LINEAR LOAD < 5.0%

MAXIMUM OVERSPEED

2250 Rev/Min

BEARING DRIVE END

BALL. 6309-2RS (ISO)

BEARING NON-DRIVE END

BALL. 6306-2RS (ISO)

 

1 BEARING

2 BEARING

 

WITH   EBS

WITHOUT   EBS

WITH   EBS

WITHOUT   EBS

WEIGHT COMP. GENERATOR

120.5 kg

118.8 kg

123.5 kg

121.8 kg

WEIGHT WOUND STATOR

44 kg

44 kg

44 kg

44 kg

WEIGHT WOUND ROTOR

41.87 kg

40.17 kg

42.87 kg

41.17 kg

WR² INERTIA

0.156 kgm2

0.1544 kgm2

0.1562 kgm2

0.1545 kgm2

SHIPPING WEIGHTS in a crate

138 kg

136.3 kg

147 kg

145.3 kg

PACKING CRATE SIZE

71 x 51 x 67 (cm)

71 x 51 x 67 (cm)

TELEPHONE INTERFERENCE

THF<2%

TIF<50

COOLING AIR

0.122 m³/sec  251 cfm

VOLTAGE SERIES

220

230

240

VOLTAGE PARALLEL

110

115

120

POWER FACTOR

0.8

1.0

0.8

1.0

0.8

1.0

kVA BASE RATING FOR REACTANCE VALUES

 

15.7

 

21.0

 

16.3

 

21.0

 

17.0

 

21.0

Xd DIR. AXIS SYNCHRONOUS

1.68

2.25

1.60

2.06

1.53

1.89

X'd DIR. AXIS TRANSIENT

0.18

0.24

0.17

0.22

0.16

0.20

X''d DIR. AXIS SUBTRANSIENT

0.11

0.15

0.10

0.13

0.10

0.12

Xq QUAD. AXIS REACTANCE

0.81

1.08

0.77

0.99

0.74

0.91

X''q QUAD. AXIS SUBTRANSIENT

0.18

0.24

0.17

0.22

0.16

0.20

XL LEAKAGE REACTANCE

0.07

0.09

0.06

0.08

0.06

0.07

X2 NEGATIVE SEQUENCE

0.14

0.19

0.14

0.18

0.13

0.16

X0 ZERO SEQUENCE

0.07

0.09

0.06

0.08

0.06

0.07

REACTANCES ARE SATURATED                                       VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED

T'd TRANSIENT TIME CONST.

0.017 s

T''d SUB-TRANSTIME CONST.

0.004 s

T'do O.C. FIELD TIME CONST.

0.38 s

Ta ARMATURE TIME CONST.

0.007 s

SHORT CIRCUIT RATIO

1/Xd

Spec#4 Control System ComAp InteliLite® MRS10

18KW Silent Type 4 Stoke Perkins Diesel Generators  With Water Cooling

 

 

 

18KW Silent Type 4 Stoke Perkins Diesel Generators  With Water Cooling

Spec #4.1 Features

1

Automatic or manual start/stop of the gen-set

2

Push buttons for simple control, lamp test

3

Lockable battery isolator switch

4

Graphic back-lit LCD display 128×64 pixels

5

2 LED indicators

6

Integrated wiring design

7

Parameters adjustable via keyboard or PC

8

Generator measurements (50/60 Hz):U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh

9

Selectable protections alarm/ shutdown

10

3 phase Generator protections

– Over-/under voltage

– Over-/under frequency

– Current/voltage asymmetry

– Overcurrent/overload

11

Analog oil pressure, water, temperature, fuel level, battery, voltage, engine speed (pick-up)

12

Configurable programmable inputs and outputs

13

Warm-up and cooling functions

14

RS232 interface (AT-LINK CONV cable is necessary for IL-MRS 10)

15

Dimensions 180×120 mm (front panel)

16

Sealed to IP65

17

Custom-made is acceptable

Spec #4.2 Functions

Binary inputs/oupputs

6/6

Analog inputs

3

Pick-up

-

AMF function

-

Input configuration

Output configuration

Voltage measurement Gen./Mains

3ph/-

Current measurement

3ph

KW/KWH measurement

●/-

GCB/MCB control with feedback

 

Extension units(periph)

-

Communication interfaces

Rs232

Modem support

-

Battery charging alternator circuit

Spec #5 Options

 

Items

Options

Select

Engine

Water Jacket Preheater

 

Oil Preheater

 

Alternator

Winding Temperature Measuring Instrument

 

Alternator Preheater

 

PMG

 

Anti-damp and anti-corrosion treatment

 

Anti-condensation heater

 

Generator Set

Tools with the machine

STND

Fuel System

Low fuel level alarm

 

Automatic fuel feeding system

 

Fuel T-valves

 

Enclosure

Open Type

 

Silent/Super Silent Type

 

Trailer Type

 

Canopy/Enclosure Type

 

Lubricating sys

Oil with the machine

 

Exhaust Sys.

Protection board from hotness

 

Cooling Sys.

Front heat protection

 

Coolant (-30°C)

 

Control System

Remote Control System

 

ATS Control System

 

Auto Synchronizing System

 

Generator Set Output Cabinet

 

Control Panel

Czech·ComAp

STND

China·Hidier

 

Denmark·Deif

 

U.K.·Deepsea

 

Voltages

415/240V

 

400/230V

 

380/220V

 

220/127V

 

200-115V

 

 

Contact Details
Hidier Power Group (Beijing) Co., Ltd.

Contact Person: Mr. Yang Congli(Colin)

Tel: +86 13370160269

Fax: 86-10-59602578