|
Product Details:
Payment & Shipping Terms:
|
Output Capacity: | 1372/1500kVA | Output Power: | 1200/1200kW |
---|---|---|---|
Genset Type: | Hidier | Engine: | Perkins |
Frequency: | 50Hz / 60Hz | Cooling Type: | Water Cooled |
High Light: | Perkins Diesel Generator Set,Perkins Diesel Genset |
50 / 60HZ Perkins Diesel Generators With Induction System , 1200KW Water Cooled
HDP Series HDP1200/ HDP1200S |
Model |
Standby Power |
Prime Power |
Engine |
Alternator |
Control Panel |
|||
KVA |
KW |
KVA |
KW |
Stamford |
Hidier(Optional) |
Model |
||
HDP1200/S |
1500 |
1200 |
1375 |
1100 |
4012-46TWG3A |
PI734B |
HD1100 |
MRS10 |
Spec #1.1 Features |
|
1 |
Excitation system: self-excited (AREP and PMG are optional) |
2 |
ATS (automatic transfer switch) receptacle |
3 |
Lockable battery isolator switch |
4 |
Stainless galvanized zinc plates with strong corrosion resistance |
5 |
Vibration isolators between the engine/alternator and base frame |
6 |
Integrated wiring design |
7 |
Base fuel tank for at least 8 hours running |
8 |
Equipped with an industrial muffler |
9 |
50℃ radiator |
10 |
Top lifting and steel base frame with forklift holes |
11 |
Drainage for fuel tank |
12 |
Complete protection functions and safety labels |
13 |
IP54 (soundproof sets), IP56 (control system) |
14 |
Water jacket preheater, oil heater are available. |
15 |
Double air cleaner, spare parts, special tools are available. |
16 |
Custom-made is acceptable |
Ratings and Performance Data | |||
Engine Brand & Model: | Perkins 4012-46TWG3A | ||
Alternator Brand & Model: | Stamford PI734B | ||
Control System: | ComAp InteliLite®MRS10 | ||
Noise Level@7m: | 80-95 | ||
Frequency & Phase: | 50Hz & 3 Phase | ||
Engine Speed: RPM | 1500 | ||
Structure Type: | HDP1200 | ||
HDP1200S | |||
Fuel Tank Capacity: L | HDP1200 | / | |
HDP1200S | / | ||
Fuel Consumption: l/hr (100% Load) | Prime | / | |
Standby | / |
Generator Set | Length (L) | Width (W) | Height (H) | Net Weight kg |
Model | mm | mm | mm | |
HDP1200 | 5200 | 2100 | 2600 | 9800 |
HDP1200S | 12200 | 2400 | 3200 | 19800 |
Spec #1.2 Container Calculation |
||||
Generator Set Model |
20’GP pcs |
40‘GP pcs |
40‘HQ pcs |
Efficiency |
HDP1620 |
N/A |
N/A |
N/A |
N/A |
HDP1620S |
N/A |
N/A |
N/A |
N/A |
Spec#2 Engine Perkins 4012-46TWG3A
|
|
Spec #2.2 Engine Output |
|||||||
Speed rpm |
Run Type |
Typical Output (Net) |
Engine Power |
||||
Gross |
Net |
||||||
kVA |
kWe |
kWm |
hp |
kWm |
hp |
||
1500 |
Prime |
1364 |
1092 |
1207 |
1618 |
1149 |
1540 |
Standby |
1500 |
1200 |
1321 |
1772 |
1263 |
1694 |
|
1800 |
Prime |
1364 |
1092 |
1207 |
1618 |
1149 |
1540 |
Standby |
1500 |
1200 |
1321 |
1772 |
1263 |
1694 |
*Subject to conformance with ASTM D6751 and EN14214.
The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating may be required for conditions outside these; consult Perkins Engines Company Limited. Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8.
Fuel specification: BS 2869: Part 2 1998 Class A2 or ASTM D975 D2.
Rating Definitions:
Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours operation.
Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.
Spec #2.3 Fuel System |
|||||
Type of injection |
Direct |
||||
Fuel injection pump |
Combined unit injector |
||||
Fuel injector opening pressure |
23.4MPa |
||||
Delivery/hour at 1500 rpm |
1020 litres |
||||
Electronic governor (optional) |
Heat retained in fuel to tank.. |
||||
Fuel lift pump |
|||||
Fuel lift pump pressure |
300 kPa |
||||
Maximum suction head |
24,5 kPa |
||||
Maximum pressure head |
See Installation Manual |
||||
Fuel filter spacing |
10 microns |
||||
Governor type |
.Electronic |
||||
Torque at the governor output |
/ |
||||
Fuel specification |
|||||
USA Fed Off Highway - EPA2D 89.330-96 |
|||||
Europe Off Highway - CEC RF-06-99 |
|||||
Fuel Consumption |
|||||
Engine Speed |
g/kWh |
Litres/hr |
|||
1500 |
1800 |
1500 |
1800 |
||
At Standby Max power |
215 |
- |
315 |
- |
|
At Prime Power rating |
211 |
- |
281 |
- |
|
75% of prime power |
212 |
- |
212 |
- |
|
50% of prime power |
224 |
- |
149 |
- |
Spec #2.4 Cooling System |
|||
Total coolant capacity |
|||
Engine only |
73 litres |
||
Electropak (engine and radiator): |
|||
-temperate |
196 litres |
||
-tropical |
201 litres |
||
Thermostat operating range |
71 - 85 °C |
||
Coolant temperature shutdown |
101 °C rising |
||
Coolant immersion heater |
2x4 kWe |
||
Radiator |
|||
Radiator face area |
2,98 m² |
||
Material and number of rows: |
|||
-charge air and water jacket |
copper, 4 rows |
||
Fins per inch and material: |
|||
-charge air and water jacket |
brass, 12 rows |
||
Water jacket cooling data |
|||
Temperate and Tropical -coolant flow |
1020 litres/min |
||
-coolant exit temperature (max) . |
98 °C |
||
-coolant inlet temperature (min) |
thermostatic control |
||
Max permissible external system resistance |
kPa |
||
Thermostat operation range |
82 - 93 °C |
||
Max. static pressure head on pump |
30.4 kPa |
||
Recommended coolant |
50% anti freeze / 50% water. For complete details of recommended coolant specifications, refer to the Operation and Maintenance Manual for this engine model. |
||
Duct allowance |
|||
Maximum additional restriction (duct allowance) to cooling airflow and resultant minimum airflow |
|||
Ambient clearance 50% Glycol |
Duct allowance Pa |
m³/sec |
|
N/A |
N/A |
N/A |
|
N/A |
N/A |
N/A |
Spec #2.5 Induction System |
|
Maximum static bending moment at rear face of block |
1400 Nm |
Maximum air intake restriction |
|
-clean filter. |
2 kPa |
-dirty filter |
4 kPa |
-air filter type |
Medium duty axial flow |
Spec #2.6 Electrical System |
|||||||
type |
Insulated return |
||||||
alternator |
24 volts with integral regulator |
||||||
starter motor |
24 volts |
||||||
Starter motor power |
16.4 kW |
||||||
Number of teeth on flywheel |
156 |
||||||
Number of teeth on starter motor.. |
12 |
||||||
Minimum cranking speed (0°C) |
120 rpm |
||||||
Cold start recommendations |
|||||||
Minimum engine cranking speed over TDC |
120 rev/min |
||||||
Minimum starting temperature |
Grade of engine lubricating oil |
Battery specifications |
|||||
°C |
BS3911 Cold start amps |
SAEJ537 Cold cranking amps |
Number of batteries needed |
Commercial ref number |
|||
0 |
20W |
540 |
740 |
1 |
647 |
||
-15 |
10W |
540 |
740 |
1 |
647 |
||
-20 |
5W |
600 |
780 |
1 |
655 |
Spec #2.7 Exhaust System |
|
Exhaust outlet size (internal) |
2 x 254 mm Table D flanges |
Back pressure for total system |
5 kPa |
Emissions statement: Constant Speed Engines for use in Industrial, IOPU and ElectropaK applications: Certified against the requirements of EU Stage IIIA (Directives 97/68/EC, as last amended, for mobile applications).
Spec #2.8 Lubrication System |
||
Lubricating oil capacity |
|
|
-total system capacity |
177 litres |
|
-sump maximum |
157,5 litres |
|
-oil temperature at normal operating conditions to bearings 105 °C |
||
Lubricating oil pressure |
||
-at rated speed |
400 kPa |
|
-minimum at 80 °C |
340 kPa |
|
-oil relief values open |
400 kPa |
|
-oil filter spacing |
20 microns |
|
-oil pump speed |
2100 rev/min |
|
Normal operating angles |
||
Front and rear ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .... ..... 5° Side tilt .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 10° |
|
Spec#3 Alternator Stamford P1734B / Hidier HD1100 |
CONTROL SYSTEM |
SEPARATELY EXCITED BY P.M.G. |
|||||||
A.V.R. |
MX341 |
MX321 |
|
|||||
VOLTAGE REGULATION |
± 1% |
± 0.5 % |
With 4% ENGINE GOVERNING |
|||||
SUSTAINED SHORT CIRCUIT |
REFER TO SHORT CIRCUIT DECREMENT CURVES |
|||||||
INSULATION SYSTEM |
CLASS H |
|||||||
PROTECTION |
IP23 |
|||||||
RATED POWER FACTOR |
0.8 |
|||||||
STATOR WINDING |
DOUBLE LAYER LAP |
|||||||
WINDING PITCH |
TWO THIRDS |
|||||||
WINDING LEADS |
6 |
|||||||
MAIN STATOR RESISTANCE |
0.0016 Ohms PER PHASE AT 22°C STAR CONNECTED |
|||||||
MAIN ROTOR RESISTANCE |
1.67 Ohms at 22°C |
|||||||
EXCITER STATOR RESISTANCE |
17.5 Ohms at 22°C |
|||||||
EXCITER ROTOR RESISTANCE |
0.063 Ohms PER PHASE AT 22°C |
|||||||
R.F.I. SUPPRESSION |
BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others |
|||||||
WAVEFORM DISTORTION |
NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% |
|||||||
MAXIMUM OVERSPEED |
2250 Rev/Min |
|||||||
BEARING DRIVE END |
BALL. 6228 C3 |
|||||||
BEARING NON-DRIVE END |
BALL. 6319 C3 |
|||||||
|
1 BEARING |
2 BEARING |
||||||
WEIGHT COMP. GENERATOR |
2760 kg |
2710 kg |
||||||
WEIGHT WOUND STATOR |
1306 kg |
1306 kg |
||||||
WEIGHT WOUND ROTOR |
1139 kg |
1077 kg |
||||||
WR² INERTIA |
32.7498 kgm2 |
31.7489 kgm2 |
||||||
SHIPPING WEIGHTS in a crate |
2833kg |
2779kg |
||||||
PACKING CRATE SIZE |
194 x 105 x 154(cm) |
194 x 105 x 154(cm) |
||||||
|
50 Hz |
60 Hz |
||||||
TELEPHONE INTERFERENCE |
THF<2% |
TIF<50 |
||||||
COOLING AIR |
2.69 m³/sec 5700 cfm |
3.45 m³/sec 7300 cfm |
||||||
VOLTAGE STAR |
380/220 |
400/231 |
415/240 |
440/254 |
416/240 |
440/254 |
460/266 |
480/277 |
kVA BASE RATING FOR REACTANCE VALUES |
1360 |
1400 |
1400 |
1375 |
1525 |
1625 |
1655 |
1690 |
Xd DIR. AXIS SYNCHRONOUS |
3.50 |
3.26 |
3.02 |
2.64 |
4.25 |
4.04 |
3.77 |
3.53 |
X'd DIR. AXIS TRANSIENT |
0.21 |
0.20 |
0.18 |
0.16 |
0.26 |
0.25 |
0.23 |
0.22 |
X''d DIR. AXIS SUBTRANSIENT |
0.16 |
0.15 |
0.14 |
0.12 |
0.19 |
0.18 |
0.17 |
0.16 |
Xq QUAD. AXIS REACTANCE |
2.26 |
2.10 |
1.95 |
1.70 |
2.74 |
2.61 |
2.43 |
2.28 |
X''q QUAD. AXIS SUBTRANSIENT |
0.32 |
0.29 |
0.27 |
0.24 |
0.38 |
0.37 |
0.34 |
0.32 |
XL LEAKAGE REACTANCE |
0.04 |
0.04 |
0.03 |
0.03 |
0.05 |
0.05 |
0.04 |
0.04 |
X2 NEGATIVE SEQUENCE |
0.22 |
0.21 |
0.19 |
0.17 |
0.27 |
0.26 |
0.24 |
0.23 |
X0 ZERO SEQUENCE |
0.03 |
0.03 |
0.02 |
0.02 |
0.03 |
0.03 |
0.03 |
0.03 |
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED |
||||||||
T'd TRANSIENT TIME CONST. |
0.13s |
|||||||
T''d SUB-TRANSTIME CONST. |
0.01s |
|||||||
T'do O.C. FIELD TIME CONST. |
2.14s |
|||||||
Ta ARMATURE TIME CONST. |
0.02s |
|||||||
SHORT CIRCUIT RATIO |
1/Xd |
Spec#4 Control System ComAp InteliLite® MRS10 |
|
Spec #4.1 Features |
|
1 |
Automatic or manual start/stop of the gen-set |
2 |
Push buttons for simple control, lamp test |
3 |
Lockable battery isolator switch |
4 |
Graphic back-lit LCD display 128×64 pixels |
5 |
2 LED indicators |
6 |
Integrated wiring design |
7 |
Parameters adjustable via keyboard or PC |
8 |
Generator measurements (50/60 Hz):U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh |
9 |
Selectable protections alarm/ shutdown |
10 |
3 phase Generator protections – Over-/under voltage – Over-/under frequency – Current/voltage asymmetry – Overcurrent/overload |
11 |
Analog oil pressure, water, temperature, fuel level, battery, voltage, engine speed (pick-up) |
12 |
Configurable programmable inputs and outputs |
13 |
Warm-up and cooling functions |
14 |
RS232 interface (AT-LINK CONV cable is necessary for IL-MRS 10) |
15 |
Dimensions 180×120 mm (front panel) |
16 |
Sealed to IP65 |
17 |
Custom-made is acceptable |
Spec #4.2 Functions |
|
Binary inputs/oupputs |
6/6 |
Analog inputs |
3 |
Pick-up |
- |
AMF function |
- |
Input configuration |
● |
Output configuration |
● |
Voltage measurement Gen./Mains |
3ph/- |
Current measurement |
3ph |
KW/KWH measurement |
●/- |
GCB/MCB control with feedback |
|
Extension units(periph) |
- |
Communication interfaces |
Rs232 |
Modem support |
- |
Battery charging alternator circuit |
● |
Spec #5 Options |
|
|
Items |
Options |
Select |
Engine |
Water Jacket Preheater |
|
Oil Preheater |
|
|
Alternator |
Winding Temperature Measuring Instrument |
|
Alternator Preheater |
|
|
PMG |
|
|
Anti-damp and anti-corrosion treatment |
|
|
Anti-condensation heater |
|
|
Generator Set |
Tools with the machine |
STND |
Fuel System |
Low fuel level alarm |
|
Automatic fuel feeding system |
|
|
Fuel T-valves |
|
|
Enclosure |
Open Type |
|
Silent/Super Silent Type |
|
|
Trailer Type |
|
|
Canopy/Enclosure Type |
|
|
Lubricating sys |
Oil with the machine |
|
Exhaust Sys. |
Protection board from hotness |
|
Cooling Sys. |
Front heat protection |
|
Coolant (-30°C) |
|
|
Control System |
Remote Control System |
|
ATS Control System |
|
|
Auto Synchronizing System |
|
|
Generator Set Output Cabinet |
|
|
Control Panel |
Czech·ComAp |
STND |
China·Hidier |
|
|
Denmark·Deif |
|
|
U.K.·Deepsea |
|
|
Voltages |
415/240V |
|
400/230V |
|
|
380/220V |
|
|
220/127V |
|
|
200-115V |
|
Contact Person: Mr. Yang Congli(Colin)
Tel: +86 13370160269
Fax: 86-10-59602578