Hidier Power Group (Beijing) Co., Ltd.

                  Green Power, Hidier Power

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Company News
Home ProductsPerkins Diesel Generators

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

I'm Online Chat Now
Certification
Good quality Kohler Diesel Generator for sales
Good quality Kohler Diesel Generator for sales
Hidier is a great brand. As a distributor, we feel content to its quality, service and hope we can go on this win-win relationship.

—— Julie Thomson

We purchased an 800KW Cummins diesel generator from Hidier. Hidier is as good as world famous brand! They had office in my country.

—— Alexander Zverev

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

large.img.alt
small.img.alt

Large Image :  58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase Get Best Price

Product Details:
Place of Origin: Perkins Engine, assembled in China
Brand Name: HIDIER-Perkins
Certification: CE, CSA, NOISE, GS, EC-II, EPA, CARB, GOST.
Model Number: HDP58/S
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Plywood box
Delivery Time: Within 30 days
Payment Terms: L/C, T/T
Supply Ability: 1000pcs/week
Detailed Product Description
Output Capacity: 65/72kVA Output Power: 52/57.6kW
Type: Generator Set Engine: Perkins
Frequency: 50Hz / 60Hz Cooling Type: Water Cooled
High Light:

Perkins Diesel Generator Set

,

Perkins Diesel Genset

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

 

 

 

 HDP Series                     HDP58 / HDP58S  

Model

Standby Power

Prime Power

Engine

Alternator

Control Panel

KVA

KW

KVA

KW

Stamford

Hidier(Optional)

Model

HDP58/S

72

57.6

65

52

1104A-44TG1

UCI224E

HD52

AMF20

 

 Spec #1 Features

1

Excitation system: self-excited (AREP and PMG are optional)

2

ATS (automatic transfer switch) receptacle

3

Lockable battery isolator switch

4

Stainless galvanized zinc plates with strong corrosion resistance

5

Vibration isolators between the engine/alternator and base frame

6

Integrated wiring design

7

Base fuel tank for at least 8 hours running

8

Equipped with an industrial muffler

9

50℃ radiator

10

Top lifting and steel base frame with forklift holes

11

Drainage for fuel tank

12

Complete protection functions and safety labels

13

IP54 (soundproof sets), IP56 (control system)

14

Water jacket preheater, oil heater are available.

15

Double air cleaner, spare parts, special tools are available.

16

Custom-made is acceptable

          17           Engine oil pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

Generator Set Length (L) Width (W) Height (H) Net Weight kg
Model mm mm mm
HDP58 2200 750 1600 980
HDP58S 2500 1100 1800 1700

 

 

Spec#2  Engine         Perkins 1104A-44TG1
58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

 

       

1100 Series
1104A-44TG1
Diesel Engine - ElectropaK

64.3 kWm at 1500 rpm
75.5 kWm at 1800 rpm

     

Standard ElectropaK Specification

 

Air inlet

•  Mounted air filter

 

Fuel system

•  Rotary type pump

•  Ecoplus fuel filter

 

Lubrication system

•  Wet sump with filler and dipstick

•  Spin-on oil filter

 

Cooling system

•  Thermostatically-controlled system with gear-driven circulation pump and belt-driven pusher fan

•  Mounted radiator and piping

 

Electrical equipment

•  12 volt starter motor and 12 volt 65 amp alternator with

DC output

•  12 volt shutdown solenoid energised to run

•  Glow plug cold start aid

 

Flywheel housing

•  High inertia flywheel to SAE J620 size 10/111/2

•  SAE 3 flywheel housing

 

Literature

•  User’s Handbook

 

Optional equipment

•  Woodward electronic governor (LCG2)

•  Workshop manual

•  Parts book

 

    58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

 

 

General Data

Number of cylinders..............4 vertical in-line

Bore and stroke....................105 x 127 mm

Displacement........................4.4 litres

Aspiration..............................Turbocharged

Cycle.....................................4 stroke

Combustion system...............Direct injection

Compression ratio.................17.25:1

Rotation.................................Anti-clockwise

                                              viewed from flywheel 

Cooling system .....................Water-cooled

Total lubrication system..........8.0 litres

capacity

Total coolant capacity.............13.0 litres

Dimensions                                  

Length 1241 mm

Width    629 mm

Height   951 mm

Dry Weight (approx.)   463 kg

                
 
 
 
Engine speed rev/min   Typical Generator Engine Power
Type of Output (Net) Gross Net
Operation kVA kWe kW bhp kW bhp
1500 Prime Power 65 52 59.6 79.9 58.4 78.3
Standby Power 71.5 57.2 65.6 88 64.3 86.2
1800 Prime Power 76 60.8 70.7 94.8 68.6 92
Standby Power 83.6 66.9 77.8 104.3 75.5 101.2
 
Spec#3  Alternator     StamfordUCI224E

 

 

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase WINDINGS & ELECTRICAL PERFORMANCE
All generator stators are wound to 2/3 pitch.  This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.  The 2/3 pitch design  avoids  excessive  neutral  currents  sometimes seen with higher winding pitches, when in parallel with the mains.  A fully connected damper winding reduces oscillations during paralleling.  This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion.
TERMINALS & TERMINAL BOX
Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator.  A sheet steel terminal box contains the AVR and provides ample space  for  the  customers'  wiring  and  gland arrangements.    It   has   removable   panels   for   easy access.

58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase

 
INSULATION SYSTEM CLASS H
PROTECTION IP23
RATED POWER FACTOR 0.8
STATOR WINDING DOUBLE LAYER CONCENTRIC
WINDING PITCH TWO THIRDS
WINDING LEADS 12
STATOR WDG. RESISTANCE 0.101 Ohms PER PHASE AT 22°C  SERIES STAR CONNECTED
ROTOR WDG. RESISTANCE 0.69 Ohms at 22°C
EXCITER STATOR RESISTANCE 20 Ohms at 22°C
EXCITER ROTOR RESISTANCE 0.078 Ohms PER PHASE AT 22°C
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5%  NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED 2250 Rev/Min
BEARING DRIVE END BALL. 6312-2RS  (ISO)
BEARING NON-DRIVE END BALL. 6309-2RS  (ISO)
  1 BEARING 2 BEARING
WEIGHT COMP. GENERATOR 311 kg 330 kg
WEIGHT WOUND STATOR 103 kg 103 kg
WEIGHT WOUND ROTOR 95.89 kg 87.52 kg
WR² INERTIA 0.4999 kgm2 0.4682 kgm2
SHIPPING WEIGHTS in a crate 334 kg 351 kg
PACKING CRATE SIZE 105 x 57 x 96(cm) 105 x 57 x 96(cm)
  50 Hz 60 Hz
TELEPHONE INTERFERENCE THF<2% TIF<50
COOLING AIR 0.216 m³/sec  458 cfm 0.281 m³/sec  595 cfm
VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277
VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138
VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138
kVA BASE RATING FOR REACTANCE 60 60 60 58 67.5 70 72.5 75
VALUES
Xd DIR. AXIS SYNCHRONOUS 2.48 2.24 2.08 1.79 3 2.78 2.64 2.5
X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 0.14 0.22 0.2 0.19 0.18
X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 0.09 0.15 0.14 0.13 0.13
Xq QUAD. AXIS REACTANCE 1.13 1.02 0.95 0.82 1.38 1.28 1.21 1.15
X''q QUAD. AXIS SUBTRANSIENT 0.14 0.13 0.12 0.1 0.14 0.13 0.12 0.12
XL LEAKAGE REACTANCE 0.08 0.08 0.07 0.06 0.09 0.08 0.08 0.08
X2 NEGATIVE SEQUENCE 0.13 0.12 0.11 0.09 0.14 0.13 0.12 0.12

 

Spec#4  Control System   ComAp InteliLite®AMF20

InteliLite'"AMF 20 and InteliLite'" AMF 25 are new  integrated controllers for gen-sets operating in single standby mode. They meet all possible requirements for AMF appli  tionsincluding modem control user configuration and  full gen-set monitoring and protection.

InleliLile@> conlrollers are equipped wilh a powerful graphic disy.lc    s symbols and bar graphs for inluilive operalion logelher wilh high funclionalily

selnew slandards in gen-selconlrol. Speciallow temperature (IL-AMF 20-LT or IL-AMF 25-)version is also availableallowing the display to work

up  to -30oC.

 Features

•  Support  of engines equipped with Electronic Control Unit – J1939 interface (IL-MRS 15 only)

•  Automatic or manual start/stop of the gen-set

•   Push buttons for simple control, lamp test

•   Graphic back-lit LCD display 128×64 pixels

•   2 LED indicators

•   Parameters adjustable via keyboard  or PC

•  Generator measurements (50/60 Hz): U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh

•  Selectable protections alarm/ shutdown

•  3 phase Generator protections

    – Over-/under voltage

    – Over-/under frequency

    – Current/voltage asymmetry

    – Overcurrent/overload

•  Analog oil pressure, water temperature, fuel level, battery voltage, engine speed (pick-up) Configurable •  programmable

•  inputs and outputs

•  Warm-up and cooling functions

•  RS232 interface (AT-LINK CONV

•  cable is necessary for IL-MRS 10)

•  Modem  communication support (IL-MRS 15 only)

•  Dimensions 180×120 mm (front panel)

•  Sealed to IP65

Spec #5 Options

Items

Options

Select

Engine

Water Jacket Preheater

 

Oil Preheater

 

Alternator

Winding Temperature Measuring Instrument

 

Alternator Preheater

 

PMG

 

Anti-damp and anti-corrosion treatment

 

Anti-condensation heater

 

Generator Set

Tools with the machine

 

Fuel System

Low fuel level alarm

 

Automatic fuel feeding system

 

Fuel T-valves

 

Canopy

Trailer

 

Lubricating sys

Oil with the machine

 

Exhaust Sys.

Protection board from hotness

 

Cooling Sys.

Front heat protection

 

Coolant (-30°C)

 

Control Panel

Remote control panel

 

ATS

 

DSE

 

Voltages

415/240V

 

400/230V

 

380/220V

 

220/127V

 

200-115V

 

Contact Details
Hidier Power Group (Beijing) Co., Ltd.

Contact Person: Mr. Yang Congli(Colin)

Tel: +86 13370160269

Fax: 86-10-59602578

Send your inquiry directly to us