Product Details:
Payment & Shipping Terms:
|
Output Capacity: | 65/72kVA | Output Power: | 52/57.6kW |
---|---|---|---|
Type: | Generator Set | Engine: | Perkins |
Frequency: | 50Hz / 60Hz | Cooling Type: | Water Cooled |
High Light: | Perkins Diesel Generator Set,Perkins Diesel Genset |
58 kw 72kVA Perkins Diesel Generators Silent / Open Type 3 Phase
HDP Series HDP58 / HDP58S |
Model |
Standby Power |
Prime Power |
Engine |
Alternator |
Control Panel |
|||
KVA |
KW |
KVA |
KW |
Stamford |
Hidier(Optional) |
Model |
||
HDP58/S |
72 |
57.6 |
65 |
52 |
1104A-44TG1 |
UCI224E |
HD52 |
AMF20 |
Spec #1 Features |
|
1 |
Excitation system: self-excited (AREP and PMG are optional) |
2 |
ATS (automatic transfer switch) receptacle |
3 |
Lockable battery isolator switch |
4 |
Stainless galvanized zinc plates with strong corrosion resistance |
5 |
Vibration isolators between the engine/alternator and base frame |
6 |
Integrated wiring design |
7 |
Base fuel tank for at least 8 hours running |
8 |
Equipped with an industrial muffler |
9 |
50℃ radiator |
10 |
Top lifting and steel base frame with forklift holes |
11 |
Drainage for fuel tank |
12 |
Complete protection functions and safety labels |
13 |
IP54 (soundproof sets), IP56 (control system) |
14 |
Water jacket preheater, oil heater are available. |
15 |
Double air cleaner, spare parts, special tools are available. |
16 |
Custom-made is acceptable |
17 | Engine oil pump |
Generator Set | Length (L) | Width (W) | Height (H) | Net Weight kg |
Model | mm | mm | mm | |
HDP58 | 2200 | 750 | 1600 | 980 |
HDP58S | 2500 | 1100 | 1800 | 1700 |
Spec#2 Engine Perkins 1104A-44TG1 |
![]() ![]()
|
1100 Series 64.3 kWm at 1500 rpm
|
Standard ElectropaK Specification
Air inlet • Mounted air filter
Fuel system • Rotary type pump • Ecoplus fuel filter
Lubrication system • Wet sump with filler and dipstick • Spin-on oil filter
Cooling system • Thermostatically-controlled system with gear-driven circulation pump and belt-driven pusher fan • Mounted radiator and piping
Electrical equipment • 12 volt starter motor and 12 volt 65 amp alternator with DC output • 12 volt shutdown solenoid energised to run • Glow plug cold start aid
Flywheel housing • High inertia flywheel to SAE J620 size 10/111/2 • SAE 3 flywheel housing
Literature • User’s Handbook
Optional equipment • Woodward electronic governor (LCG2) • Workshop manual • Parts book
|
![]()
General Data Number of cylinders..............4 vertical in-line Bore and stroke....................105 x 127 mm Displacement........................4.4 litres Aspiration..............................Turbocharged Cycle.....................................4 stroke Combustion system...............Direct injection Compression ratio.................17.25:1 Rotation.................................Anti-clockwise viewed from flywheel Cooling system .....................Water-cooled Total lubrication system..........8.0 litres capacity Total coolant capacity.............13.0 litres Dimensions Length 1241 mm Width 629 mm Height 951 mm Dry Weight (approx.) 463 kg |
Engine speed rev/min | Typical Generator | Engine Power | |||||
Type of | Output (Net) | Gross | Net | ||||
Operation | kVA | kWe | kW | bhp | kW | bhp | |
1500 | Prime Power | 65 | 52 | 59.6 | 79.9 | 58.4 | 78.3 |
Standby Power | 71.5 | 57.2 | 65.6 | 88 | 64.3 | 86.2 | |
1800 | Prime Power | 76 | 60.8 | 70.7 | 94.8 | 68.6 | 92 |
Standby Power | 83.6 | 66.9 | 77.8 | 104.3 | 75.5 | 101.2 |
Spec#3 Alternator StamfordUCI224E |
![]() |
WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. |
INSULATION SYSTEM | CLASS H | |||||||
PROTECTION | IP23 | |||||||
RATED POWER FACTOR | 0.8 | |||||||
STATOR WINDING | DOUBLE LAYER CONCENTRIC | |||||||
WINDING PITCH | TWO THIRDS | |||||||
WINDING LEADS | 12 | |||||||
STATOR WDG. RESISTANCE | 0.101 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED | |||||||
ROTOR WDG. RESISTANCE | 0.69 Ohms at 22°C | |||||||
EXCITER STATOR RESISTANCE | 20 Ohms at 22°C | |||||||
EXCITER ROTOR RESISTANCE | 0.078 Ohms PER PHASE AT 22°C | |||||||
R.F.I. SUPPRESSION | BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others | |||||||
WAVEFORM DISTORTION | NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% | |||||||
MAXIMUM OVERSPEED | 2250 Rev/Min | |||||||
BEARING DRIVE END | BALL. 6312-2RS (ISO) | |||||||
BEARING NON-DRIVE END | BALL. 6309-2RS (ISO) | |||||||
1 BEARING | 2 BEARING | |||||||
WEIGHT COMP. GENERATOR | 311 kg | 330 kg | ||||||
WEIGHT WOUND STATOR | 103 kg | 103 kg | ||||||
WEIGHT WOUND ROTOR | 95.89 kg | 87.52 kg | ||||||
WR² INERTIA | 0.4999 kgm2 | 0.4682 kgm2 | ||||||
SHIPPING WEIGHTS in a crate | 334 kg | 351 kg | ||||||
PACKING CRATE SIZE | 105 x 57 x 96(cm) | 105 x 57 x 96(cm) | ||||||
50 Hz | 60 Hz | |||||||
TELEPHONE INTERFERENCE | THF<2% | TIF<50 | ||||||
COOLING AIR | 0.216 m³/sec 458 cfm | 0.281 m³/sec 595 cfm | ||||||
VOLTAGE SERIES STAR | 380/220 | 400/231 | 415/240 | 440/254 | 416/240 | 440/254 | 460/266 | 480/277 |
VOLTAGE PARALLEL STAR | 190/110 | 200/115 | 208/120 | 220/127 | 208/120 | 220/127 | 230/133 | 240/138 |
VOLTAGE SERIES DELTA | 220/110 | 230/115 | 240/120 | 254/127 | 240/120 | 254/127 | 266/133 | 277/138 |
kVA BASE RATING FOR REACTANCE | 60 | 60 | 60 | 58 | 67.5 | 70 | 72.5 | 75 |
VALUES | ||||||||
Xd DIR. AXIS SYNCHRONOUS | 2.48 | 2.24 | 2.08 | 1.79 | 3 | 2.78 | 2.64 | 2.5 |
X'd DIR. AXIS TRANSIENT | 0.19 | 0.17 | 0.16 | 0.14 | 0.22 | 0.2 | 0.19 | 0.18 |
X''d DIR. AXIS SUBTRANSIENT | 0.13 | 0.12 | 0.11 | 0.09 | 0.15 | 0.14 | 0.13 | 0.13 |
Xq QUAD. AXIS REACTANCE | 1.13 | 1.02 | 0.95 | 0.82 | 1.38 | 1.28 | 1.21 | 1.15 |
X''q QUAD. AXIS SUBTRANSIENT | 0.14 | 0.13 | 0.12 | 0.1 | 0.14 | 0.13 | 0.12 | 0.12 |
XL LEAKAGE REACTANCE | 0.08 | 0.08 | 0.07 | 0.06 | 0.09 | 0.08 | 0.08 | 0.08 |
X2 NEGATIVE SEQUENCE | 0.13 | 0.12 | 0.11 | 0.09 | 0.14 | 0.13 | 0.12 | 0.12 |
Spec#4 Control System ComAp InteliLite®AMF20 |
InteliLite'"AMF 20 and InteliLite'" AMF 25 are new integrated controllers for gen-sets operating in single standby mode. They meet all possible requirements for AMF appli tionsincluding modem control user configuration and full gen-set monitoring and protection.
InleliLile@> conlrollers are equipped wilh a powerful graphic disy.lc s symbols and bar graphs for inluilive operalion logelher wilh high funclionalily
selnew slandards in gen-selconlrol. Speciallow temperature (IL-AMF 20-LT or IL-AMF 25-)version is also availableallowing the display to work
up to -30oC.
• Support of engines equipped with Electronic Control Unit – J1939 interface (IL-MRS 15 only)
• Automatic or manual start/stop of the gen-set
• Push buttons for simple control, lamp test
• Graphic back-lit LCD display 128×64 pixels
• 2 LED indicators
• Parameters adjustable via keyboard or PC
• Generator measurements (50/60 Hz): U1-U3, I1-I3, Hz, kW, kVAr, kVArh, kWh
• Selectable protections alarm/ shutdown
• 3 phase Generator protections
– Over-/under voltage
– Over-/under frequency
– Current/voltage asymmetry
– Overcurrent/overload
• Analog oil pressure, water temperature, fuel level, battery voltage, engine speed (pick-up) Configurable • programmable
• inputs and outputs
• Warm-up and cooling functions
• RS232 interface (AT-LINK CONV
• cable is necessary for IL-MRS 10)
• Modem communication support (IL-MRS 15 only)
• Dimensions 180×120 mm (front panel)
• Sealed to IP65
Spec #5 Options |
Items |
Options |
Select |
Engine |
Water Jacket Preheater |
|
Oil Preheater |
|
|
Alternator |
Winding Temperature Measuring Instrument |
|
Alternator Preheater |
|
|
PMG |
|
|
Anti-damp and anti-corrosion treatment |
|
|
Anti-condensation heater |
|
|
Generator Set |
Tools with the machine |
|
Fuel System |
Low fuel level alarm |
|
Automatic fuel feeding system |
|
|
Fuel T-valves |
|
|
Canopy |
Trailer |
|
Lubricating sys |
Oil with the machine |
|
Exhaust Sys. |
Protection board from hotness |
|
Cooling Sys. |
Front heat protection |
|
Coolant (-30°C) |
|
|
Control Panel |
Remote control panel |
|
ATS |
|
|
DSE |
|
|
Voltages |
415/240V |
|
400/230V |
|
|
380/220V |
|
|
220/127V |
|
|
200-115V |
|
Contact Person: Mr. Yang Congli(Colin)
Tel: +86 13370160269
Fax: 86-10-59602578